+27 21 852 4719 [email protected] Mon-Fri 8:00-17:30 (SAST)
Basementadjacent Machine Room

Basementadjacent Machine Room

Browse technical resources about OM5/OS2 fiber, FC/ST connectors, distribution boxes, circulators, QSFP28, PDU, FTTR, rail transit and communication cabling.

  • Does the elevator machine room necessarily need a separate electrical control box

    Does the elevator machine room necessarily need a separate electrical control box

    All major elevator manufacturers are offering machine room-less (MRL) systems. These systems eliminate the need for a separate room to house hydraulic pumps, control panels, etc. The controller must still be located so. Each car, machine room and hoistway pit must have separate dedicated branch circuits for lighting, receptacles and HVAC, with car and machine-room lighting exempt from GFCI while required for receptacles. Overcurrent devices and disconnects must be located in machine or control spaces, be lockable. A look at Article 620. Is there not? Has this changed OR should I be looking in the, in this case MA, elevator code for. A machine room is an area where the elevator drive unit, controller, and main disconnect switches are located. However, they do present some challenges.


  • Outdoor machine room soundproof enclosure material

    Outdoor machine room soundproof enclosure material

    For top-quality noise control, our soundproofing experts recommend utilizing acoustic panels, acoustic foam, and sound-absorbing materials such as fiberglass. Disadvantages: Almost all of the room must be treated regardless of the size of the noise source. Our range of acoustic enclosures and soundproofing solutions can help you reduce noise levels, creating a quieter and more efficient work environment. Boiler Rooms - Help to minimise low-frequency noise and resonance from industrial boilers. MECART's acoustic expertise and manufacturing capabilities enable us to conceive custom designed enclosures for your machinery or equipment with the appropriate visibility, access. NOISEBLOCK™ Acoustic Enclosure Systems are custom-engineered using double-walled acoustic panels available in various material types, thicknesses, and finishes, making them suitable for many types of indoor and outdoor noise applications.

    [PDF Version]
  • DC power supply in relay protection room

    DC power supply in relay protection room

    Two sets of batteries (220v), their respective chargers and DC boards shall be used for DC supply to each 400KV control relay and protection panels as DC supply –1 and DC supply-2. Necessary arrangement for Supervision of both the incoming DC Supplies shall be. presentation of protection and control relaying. Power Supply Devices and Systems of Relay Protection brings relay protection and electrical power engineers a single, concentrated source of information on auxiliary power supply systems and devices. This design is a single board power solution that handles an ultra-wide range of both AC and DC inputs. Failure of the dc control power can render fault detection devices unable to detect faults, breakers unable to trip for fault, local and remote indication to become inoperable, etc. When the AC auxiliary source sags or is lost, the DC system.

    [PDF Version]
  • Standard specifications are selected for optical cables used in the computer room

    Standard specifications are selected for optical cables used in the computer room

    This article introduces and explains the scope, application, and practical relevance of the eight most widely used fiber and optical cable standards: ITU-T G. 657, IEC 60793, IEC 60794, TIA-568. Fiber optic networks rely on a foundation of rigorous international standards that define. This document outlines the recommendations for single-mode optical fiber cables used in telecommunication networks within buildings, focusing on their mechanical and environmental characteristics. Transition methods used to maintain optical fiber polarity and ensure connectivity between transmitters and receivers. ANSI/TIA-568-C. The ANSI/TIA-568-C standard is a crucial set of guidelines used in designing and installing fiber optic cabling systems for telecommunications and data networks.


  • Should the cable trays in the low-voltage room be sealed off

    Should the cable trays in the low-voltage room be sealed off

    Due to their exposure to the open air because of the cable trays, the wires contained within need a very durable outer covering. The regulations dictate that the cables must either be Type TC (also known as Tray Rated) or must be metal-armored (Type MC). Ventilation, Cooling, and Environmental Conditions Switchgear generates heat during normal operation; excessive temperature can reduce equipment life and reliability. Separation isn't just an EMI precaution — it protects signaling, reduces rework, and ensures pathways meet inspection expectations across risers, plenums, and shared trays. The reorganized NEC (NFPA 70) Chapter 7 limited energy articles, paired with TIA‑569‑E pathway requirements, define how these. The primary rulebook used in the safe use of cable trays is NEC Article 392. This is a description of how to select, install, and support these metal or plastic frames, on which electrical wires are installed. Question: What are the OSHA requirements for guarding cable trays that are mounted less than 8 feet above the working surface and accessible to unqualified workers? Response: If the wiring is.

    [PDF Version]
  • Cable management rack order in the computer room

    Cable management rack order in the computer room

    Horizontal cable management organizes patch cords within individual rack units, guiding cables between equipment on the same rack level. This method helps maintain neatness and accessibility within the rack while ensuring efficient airflow and ease of maintenance. It is important to follow allel groups or in loops may create electromagnetic interfer nce (EMI) due to induction. EMI can cause errors in data transmission over these cables. Whenever possible, power cables. Effective cable management within a server rack is the cornerstone of a structured, high-performance, and maintainable IT infrastructure. Neatly routed cable connections provide the basis for the smooth operation of network and server components. This isn't just about making things look neat, it's about building a long-term system that will serve your organization. Poor cabling practices create more than visual chaos in your server room.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic and telecom products

Get a Quote